Resumen: Purpose. To assess the repeatability of the Galilei dual Scheimpflug analyzer (GDSA) in anterior segment examination. Methods. Fifty-two eyes from 52 healthy volunteers were prospectively and consecutively recruited. Anatomic, axial, refractive, and instantaneous parameters were measured with GDSA to provide a complete characterization of the anterior segment. Repeatability was assessed calculating intraclass correlation coefficient (ICC), and coefficient of variation (COV). Results. Correlation among repeated measurements showed almost perfect reliability (ICC > 0.81) for all parameters except thinnest central corneal thickness (CCT) (0.78), corneal thickness average out (0.79), and posterior axial curvature average out (0.60). Repeatability was excellent (COV 10%) for all parameters except anterior chamber volume and, superior iridocorneal angle and eccentricities. In these last three parameters, repeatability limits were excessively high compared to the mean. Conclusions. GDSA in healthy young persons had an almost perfect correlation in measuring anatomic, axial, instantaneous, and refractive parameters with greater variability for peripheral terms. Repeatability of anatomical parameters like pachymetry, anterior chamber, or iridocorneal angle and eccentricity were limited. In healthy young persons, the other evaluated parameters had very good repeatability and their limits of agreement showed excellent clinical results for this device.
Idioma: Inglés
DOI: 10.1155/2014/808646
Año: 2014
Publicado en: BioMed Research International (2014), 808646 [6 pp]
ISSN: 2314-6133

Factor impacto JCR: 1.579 (2014)
Categ. JCR: MEDICINE, RESEARCH & EXPERIMENTAL rank: 85 / 123 = 0.691 (2014) - Q3 - T3
Categ. JCR: BIOTECHNOLOGY & APPLIED MICROBIOLOGY rank: 106 / 162 = 0.654 (2014) - Q3 - T2

Financiación: info:eu-repo/grantAgreement/ES/MINECO/FIS2011-22496
Financiación: info:eu-repo/grantAgreement/ES/UZ/UZ2011-BIO-02
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Oftalmología (Departamento de Cirugía, Ginecología y Obstetricia)
Área (Departamento): Fisiología (Departamento de Farmacología y Fisiología)


Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace. No puede utilizar el material para una finalidad comercial. Si remezcla, transforma o crea a partir del material, no puede difundir el material modificado.


0
Exportado de SIDERAL (2017-01-03-12:05:18)

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Oftalmología
Artículos > Artículos por área > Fisiología

Visitas


 Registro creado el 2016-12-15, última modificación el 2017-01-03


Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)