Initial performance of the CUORE-0 experiment

Artusa, D. R. ; Avignone III, F.T. ; Azzolini, O. ; Balata, M. ; Banks, T. I. ; Bari, G. ; Beeman, J. ; Bellini, F. ; Bersani, A. ; Biassoni, M. ; Brofferio, C. ; Bucci, C. ; Cai, X. Z. ; Canonica, L. ; Cao, X. G. ; Capelli, S. ; Carbone, L. ; Cardani, L. ; Carrettoni, M. ; Casali, N. ; Chiesa, D. ; Chott, N. ; Clemenza, M. ; Cosmelli, C. ; Cremonesi, O. ; Creswick, R. J. ; Dafinei, I. ; Dally, A. ; Datskov, V. ; Deninno, M. M. ; Di Domizio, S. ; di Vacri, M. L. ; Ejzak, L. ; Fang, D. Q. ; Farach, H. A. ; Faverzani, M. ; Fernandes, G. ; Ferri, E. ; Ferroni, F. ; Fiorini, E. ; Freedman, S. J. ; Fujikawa, B. K. ; Giachero, A. ; Gironi, L. ; Giuliani, A. ; Goett, J. ; Gorla, P. ; Gotti, C. ; Gutierrez, T. D. ; Haller, E. E. ; Han, K. ; Heeger, K. M. ; Hennings-Yeomans, R. ; Huang, H. Z. ; Kadel, R. ; Kazkaz, K. ; Keppel, G. ; Kolomensky, Y. G. ; Li, Y. L. ; Lim, K. E. ; Liu, X. ; Ma, Y. G. ; Maiano, C. ; Maino, M. ; Martínez Pérez, María Lucía (Universidad de Zaragoza) ; Maruyama, R. H. ; Mei, Y. ; Moggi, N. ; Morganti, S. ; Nisi, S. ; Nones, C. ; Norman, E. B. ; Nucciotti, A. ; O¿Donnell, T. ; Orio, F. ; Orlandi, D. ; Ouellet, J. L. ; Pallavicini, M. ; Palmieri, V. ; Pattavina, L. ; Pavan, M. ; Pedretti, M. ; Pessina, G. ; Pettinacci, V. ; Piperno, G. ; Pirro, S. ; Previtali, E. ; Rosenfeld, C. ; Rusconi, C. ; Sala, E. ; Sangiorgio, S. ; Scielzo, N. D. ; Sisti, M. ; Smith, A. R. ; Taffarello, L. ; Tenconi, M. ; Terranova, F. ; Tian, W. D. ; Tomei, C. ; Trentalange, S. ; Ventura, G. ; Vignati, M. ; Wang, B. S. ; Wang, H. W. ; Wielgus, L. ; Wilson, J. ; Winslow, L. A. ; Wise, T. ; Zanotti, L. ; Zarra, C. ; Zhu, B. X. ; Zucchelli, S.
Resumen: CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of 130Te. We present the first data analysis with 7.1kg·y of total TeO2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57MeV) and in the a background-dominated region (2.70 to 3.90MeV) have been measured to be 0.071±0.011 and 0.019±0.002counts/(keV·kg·y), respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7keV. Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.
Idioma: Inglés
DOI: 10.1140/epjc/s10052-014-2956-6
Año: 2014
Publicado en: EUROPEAN PHYSICAL JOURNAL C 74, 8 (2014), 1-7
ISSN: 1434-6044

Factor impacto JCR: 5.084 (2014)
Categ. JCR: PHYSICS, PARTICLES & FIELDS rank: 5 / 27 = 0.185 (2014) - Q1 - T1
Tipo y forma: Artículo (Versión definitiva)
Área (Departamento): Física Teórica (Departamento de Física Teórica)

Creative Commons Debe reconocer adecuadamente la autoría, proporcionar un enlace a la licencia e indicar si se han realizado cambios. Puede hacerlo de cualquier manera razonable, pero no de una manera que sugiera que tiene el apoyo del licenciador o lo recibe por el uso que hace.


0
Exportado de SIDERAL (2016-12-14-12:23:03)

Este artículo se encuentra en las siguientes colecciones:
Artículos > Artículos por área > Física Teórica

Visitas


 Registro creado el 2016-12-14, última modificación el 2016-12-14


Valore este documento:

Rate this document:
1
2
3
 
(Sin ninguna reseña)