000056665 001__ 56665
000056665 005__ 20170103120924.0
000056665 0247_ $$2doi$$a10.7149/OPA.49.2.48590
000056665 0248_ $$2sideral$$a95870
000056665 037__ $$aART-2016-95870
000056665 041__ $$aspa
000056665 100__ $$aCirac, Eva
000056665 245__ $$aReliability of near stereoacuity tests: Titmus, Randot, TNO, and Frisby - Fiabilidad de los test de estereopsis de cerca: Titmus, Randot, TNO y Frisby
000056665 260__ $$c2016
000056665 5060_ $$aAccess copy available to the general public$$fUnrestricted
000056665 5203_ $$aThe purpose of this paper was to assess the reliability of four standard stereotests and evaluate them by means of their failure rates. Near stereoacuity in 200 healthy young volunteers (24±8 years), was measured with Titmus, Randot, TNO, and Frisby tests. The stereoacuity provided by these four tests were evaluated. Stereoacuity by the normal population, with a limit of 85% of the people, rises 70" with Randot and 120" with TNO independently of gender. Females achieve 80" with Titmus and 30" with Frisby and males reach 140" and 40" with Titmus and Frisby respectively. Failure rates lower than 10% were obtained by all the tests. This study finds differences among stereoacuity measured with different tests and recommends performing, at least, two types of test to evaluate each person.
La finalidad de este trabajo ha sido valorar la fiabilidad de cuatro test de estereopsis y evaluarlos por
medio de sus tasas de fallo. Se midió la estereoagudeza en visión próxima de 200 jóvenes voluntarios
sanos (24±8 años), con los test Titmus, Randot, TNO y Frisby. Se evaluó la estereopsis proporcionada
por estos cuatro test. La estereoagudeza en una población normal, con un límite del 85% alcanza 70”
con Randot y 120” con TNO independientemente del género del sujeto. Las mujeres alcanzan 80” con
Titmus y 30” con Frisby y los hombres 140” y 40” con Titmus y Frisby respectivamente. Se
obtuvieron tasas de error menores del 10% en todos los test. Este estudio muestra diferencias entre
la estereoagudeza medida con distintos test y se recomienda, realizar dos tipos de test para evaluar a
cada sujeto.
000056665 540__ $$9info:eu-repo/semantics/openAccess$$aAll rights reserved$$uhttp://www.europeana.eu/rights/rr-f/
000056665 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/publishedVersion
000056665 700__ $$0(orcid)0000-0002-2523-8598$$aJarabo Lallana, Sebastián$$uUniversidad de Zaragoza
000056665 700__ $$0(orcid)0000-0002-5621-1937$$aSánchez Cano, Ana Isabel$$uUniversidad de Zaragoza
000056665 7102_ $$12002$$2647$$aUniversidad de Zaragoza$$bDepartamento de Física Aplicada$$cOptica
000056665 773__ $$g49, 2 (2016), 101-107$$pOpt. pura apl.$$tOptica pura y aplicada$$x0030-3917
000056665 8564_ $$s167473$$uhttp://zaguan.unizar.es/record/56665/files/texto_completo.pdf$$yVersión publicada
000056665 8564_ $$s92560$$uhttp://zaguan.unizar.es/record/56665/files/texto_completo.jpg?subformat=icon$$xicon$$yVersión publicada
000056665 909CO $$ooai:zaguan.unizar.es:56665$$particulos$$pdriver
000056665 951__ $$a2017-01-03-12:05:21
000056665 980__ $$aARTICLE